As the weather gradually warms up, flowers bloom, and the cold air of winter finally passes。We finally don't have to worry about the cold air affecting the air compressor, butPrecautions for using air compressors in springDo you know?Xiaobian has sorted out some precautions for the use of air compressors in spring:
1, do a good job of cleaning the machine, after the long-term operation of the air compressor, it is prohibited to wash with cold water。
2, the spring and autumn season pay attention to the accumulation of catkins on the surface of the cooler, should be cleaned regularly to prevent the machine from high temperature。
3, the air compressor should be parked away from steam, gas and dust flying place。The intake pipe shall be equipped with a filter device。After the air compressor is in place, the pad should be symmetrically wedged。
4、Operators should be specially trained, must fully understand the structure, performance and role of air compressors and ancillary equipment, familiar with operation and maintenance procedures。Work clothes should be worn, and lesbians should tuck their braids into their work caps。It is forbidden to operate after drinking, do not engage in things unrelated to operation, do not leave the work without authorization, and do not decide to replace the work of non-local operators without authorization。
5、Keep the outside of the storage tank clean regularly。Welding or hot working in the vicinity of gas storage tanks is prohibited。The gas tank should be tested once a year, and the test pressure should be working pressure 1.5倍。Pressure gauges and safety valves should be inspected once a year。
6, before starting the air compressor, check and prepare according to the regulations, pay attention to open all the valves of the gas tank。After the diesel engine starts, it must be heated at low speed, medium speed and rated speed, and pay attention to whether the reading of each instrument is normal before it can run with load。The air compressor should gradually increase the load to start, and all parts can be operated at full load after normal。
7, when the air compressor is shut down, the exhaust valve of the gas tank should be gradually opened, the pressure should be slowly reduced, and the diesel engine speed should be reduced accordingly, so that the air compressor runs for 5 to 10 seconds without load and at low speed。After the air compressor stops, the diesel engine continues to run for 5 seconds at low speed and then stops。In winter, the temperature is less than 5 degrees, and the cooling water without antifreeze should be discharged after shutdown。
8, During the operation of the air compressor, always pay attention to the instrument reading (especially the reading of the barometer), listen to the sound of each part, if you find abnormal conditions, you should immediately stop the check。The maximum atmospheric pressure in the tank shall not exceed the pressure specified on the nameplate。Every 2 to 4h, the condensate oil and water discharge valve of the intercooler and the gas tank should be opened 1 to 2 times。Do a good job of cleaning the machine, after the long-term operation of the air compressor, it is prohibited to wash with cold water。
9, when cleaning the heat sink, do not use burning methods to remove pipeline oil。Cleaning, fastening and other maintenance work must be carried out after shutdown。When blowing parts with compressed air, it is strictly prohibited to point the air outlet at the human body or other equipment to prevent injury and damage。
10, a regular (weekly) manual exhaust test of the gas tank safety valve to ensure the safety and effectiveness of the safety valve。
The above is a simple summary of the precautions for the use of air compressors in spring. I hope you must not ignore the precautions for the use of air compressors in spring。Only by using air compressors in the spring can we avoid the loss rate of air compressors to a greater extent。